Water-heating block-modular boiler houses
Showing all 14 results
46 951 460 ₸
- Тепловая мощность, МВт (Гкал) 0,2 (0,17)
- DHW capacity (+5/+65), m3/hour 0,5
- Coolant temperature on the boiler circuit, °C +105/+90
- Coolant temperature on the external heating circuit, °C +95/+70
- Coolant volume, l (no more, taking into account expansion tanks) 1,000
- Fuel consumption for gas equipment, nm.cub./hour 24
- Fuel consumption for diesel equipment, kg/hour 19
52 222 152 ₸
- Тепловая мощность, МВт (Гкал) 0,2 (0,17)
- Coolant temperature on the boiler circuit, °C +105/+90
- Coolant temperature on the external heating circuit, °C +95/+70
- Coolant volume, l (no more, taking into account expansion tanks) 1,000
- Производительность ГВС (+5/+65) 0,03 ГКал, м3/час 0,5
- Fuel consumption for gas equipment, nm.cub./hour 24
- Fuel consumption for diesel equipment, kg/hour 19
52 822 220 ₸
- Тепловая мощность, МВт (Гкал) 0,5 (0,43)
- Coolant temperature on the boiler circuit, °C +105/+90
- Coolant temperature on the external heating circuit, °C +95/+70
- Coolant volume, l (no more, taking into account expansion tanks) 1,000
- Fuel consumption for gas equipment, nm.cub./hour 59
- Fuel consumption for diesel equipment, kg/hour 56
- Reaching operating mode, min. 30
59 382 367 ₸
- Тепловая мощность, МВт (Гкал) 0,5 (0,43)
- DHW capacity (+5/+65), m3/hour 1,3
- Coolant temperature on the boiler circuit, °C +105/+90
- Coolant temperature on the external heating circuit, °C +95/+70
- Coolant volume, l (no more, taking into account expansion tanks) 1,000
- Fuel consumption for gas equipment, nm.cub./hour 59
- Fuel consumption for diesel equipment, kg/hour 56
68 207 995 ₸
- Тепловая мощность, МВт (Гкал 1 (0,86)
- Coolant temperature on the boiler circuit, °C +105/+90
- Coolant temperature on the external heating circuit, °C +95/+70
- Coolant volume, l (no more, taking into account expansion tanks) 2,000
- Fuel consumption for gas equipment, nm.cub./hour 118
- Fuel consumption for diesel equipment, kg/hour 93
- Reaching operating mode, min. 60
81 835 790 ₸
- Total thermal power, MW (Gcal) 1 (0,86)
- DHW capacity (+5/+65), m3/hour 2,6
- Coolant temperature on the boiler circuit, °C +105/+90
- Coolant temperature on the external heating circuit, °C +95/+70
- Coolant volume, l (no more, taking into account expansion tanks) 2,000
- Fuel consumption for gas equipment, nm.cub./hour 118
- Fuel consumption for diesel equipment, kg/hour 93
82 318 930 ₸
- Тепловая мощность, МВт (Гкал 1,4 (1,2)
- Coolant temperature on the boiler circuit, °C +105/+90
- Coolant temperature on the external heating circuit, °C +95/+70
- Coolant volume, l (no more, taking into account expansion tanks) 6,000
- Fuel consumption for gas equipment, nm.cub./hour 177
- Fuel consumption for diesel equipment, kg/hour 139
- Reaching operating mode, min. 60
97 554 485 ₸
- Total thermal power, MW (Gcal) 1,4 (1,2)
- DHW capacity (+5/+65), m3/hour 4,0
- Coolant temperature on the boiler circuit, °C +105/+90
- Coolant temperature on the external heating circuit, °C +95/+70
- Coolant volume, l (no more, taking into account expansion tanks) 6,000
- Fuel consumption for gas equipment, nm.cub./hour 177
- Fuel consumption for diesel equipment, kg/hour 139
101 744 404 ₸
- Тепловая мощность, МВт (Гкал 2 (1,72)
- Coolant temperature on the boiler circuit, °C +105/+90
- Coolant temperature on the external heating circuit, °C +95/+70
- Coolant volume, l (no more, taking into account expansion tanks) 6,000
- Fuel consumption for gas equipment, nm.cub./hour 236
- Fuel consumption for diesel equipment, kg/hour 185
- Reaching operating mode, min. 60
124 053 291 ₸
- Total thermal power, MW (Gcal) 2 (1,72)
- DHW capacity (+5/+65), m3/hour 5,3
- Coolant temperature on the boiler circuit, °C +105/+90
- Coolant temperature on the external heating circuit, °C +95/+70
- Coolant volume, l (no more, taking into account expansion tanks) 6,000
- Fuel consumption for gas equipment, nm.cub./hour 236
- Fuel consumption for diesel equipment, kg/hour 185
134 182 178 ₸
- Тепловая мощность, МВт (Гкал 3 (2,58)
- Coolant temperature on the boiler circuit, °C +105/+90
- Coolant temperature on the external heating circuit, °C +95/+70
- Coolant volume, l (no more, taking into account expansion tanks) 6,400
- Fuel consumption for gas equipment, nm.cub./hour 355
- Fuel consumption for diesel equipment, kg/hour 335
- Reaching operating mode, min. 60
172 061 975 ₸
- Total thermal power, MW (Gcal) 3 (2,58)
- DHW capacity (+5/+65), m3/hour 7,9
- Coolant temperature on the boiler circuit, °C +105/+90
- Coolant temperature on the external heating circuit, °C +95/+70
- Coolant volume, l (no more, taking into account expansion tanks) 6,400
- Fuel consumption for gas equipment, nm.cub./hour 355
- Fuel consumption for diesel equipment, kg/hour 335
163 696 752 ₸
- Тепловая мощность, МВт (Гкал 4 (3,44)
- Coolant temperature on the boiler circuit, °C +105/+90
- Coolant temperature on the external heating circuit, °C +95/+70
- Coolant volume, l (no more, taking into account expansion tanks) 12000
- Fuel consumption for gas equipment, nm.cub./hour 473
- Fuel consumption for diesel equipment, kg/hour 371
- Reaching operating mode, min. 60
212 022 116 ₸
- Total thermal power, MW (Gcal) 4 (3,44)
- DHW capacity (+5/+65), m3/hour 10,6
- Coolant temperature on the boiler circuit, °C +105/+90
- Coolant temperature on the external heating circuit, °C +95/+70
- Coolant volume, l (no more, taking into account expansion tanks) 12000
- Fuel consumption for gas equipment, nm.cub./hour 473
- Fuel consumption for diesel equipment, kg/hour 371